Yantai Funaike Heat Exchanger Co.,Ltd.

Products

Tube Plate Radiator(Copper,Stainless-Steel,Aluminum)

Generator and Generator Set

Electric Power System

Electric Power System


Tube Plate Heat Exchanger for Generator
  • Feature
  • Parameters

Feature

Tube Plate Heat Exchanger for Generator

Parameters

 Tube Plate Heat Exchanger
Series DL  Electric Power System
Parameters External Size:2*1.5*0.5                                                    
Heat Exchanger:120KW                                                
Heat Echanger Surface:95㎡                                     
Operating Pressure(Mpa):0.2~4                                            
Feature/structure  Heat Rejection Module:Round Tube and Fins (Expanded Joint)                                    
Tube Rows:3-30 rows                                                    
Application Generator
Advantage The fins is made through high-speed punching by adopting material copper foil、aluminum foil or coated metal;
The base tube is adopted alloy tube and copper tube;
fins and tube holes are all expanded joint by using special equipemnt and tools. 
The advantage is with flexible design、compact structure,
high-efficient heat exchanging, it has been pursued by global 
low pressure energy heating exchanging field.
Maintenance 1.when cooler is operate normally,the temperature between cold water 
and cold air must be often checked . 
If the operating temperature is higher than temperature difference guaranteed, 
it maybe air existed in the cooler,venting method can solve this problem.
2.Mechanical washing,If sediment is found when maintenance,tube must be washed.
All tubes have to be brushed with the cleaning brush in wet state. 
Sediment residue should be rinsed after brushing.
New gaskets should be changed when installing headers.
3.If mechanical cleaning is not successful ,chemical cleaning is required. 
The chemical cleaning should be done by a competent company.  
Cleaning work should be as easy as possible,and no cleaning residue is left in the cooling system.
Please pay attention to new protective film to be formed.