Oil and gas equipment-JR525

Oil and gas equipment-JR525


Aluminum Plate-bar Heat Exchanger for Acid Fracturing Skid
  • Feature
  • Parameters

Feature

Aluminum Plate-bar Heat Exchanger for Acid Fracturing Skid

Parameters

Aluminum Plate-bar Heat Exchanger for Acid Fracturing Skid 
Model JR525
ParametersCore Size: 1410X1188X150mm                               
Core Size: 1760X1200X715mm                         
Engine: DDC S60 525HP                                  
Fan:  Blowed                                        
Heat Exchanger: 300KW                                 
Radiator Operation Pressure: 0.3mpa                      
Oil Cooler Operation Pressure: 2mpa         
Intercooler Operation Pressure: 0.4mpa             
Feature/StructurePlate-bar structure with water radiator /oil cooler/intercooler/fuel oil structure . 
The advantage is compact structure,surface area can be 1000~2500m/m because of expansion of plate-fin heat exchanger with the quadratic surface.                               
ApplicationApplcaition to Acid fracturing skid
AdvantageWith High Efficency of Heat Transfer;Well adapted,Plate-fin heat exchanger can be applied to: gas - gas, gas-liquid and liquid-liquid;Pressure Strength Resistant Capability is high.(Max 4.0Mpa);Low temperature resistant capability is strong(Ambient Tem.-65°C);Fin lodging resistance capability is strong, easy to maintain, flush.
Maintenance1.Regularly check internal medium quality of heat exchanger,if there is particles、floc matter etc, need exchange in time; 
2.Regularly check outside channel of heat exchanger,if there is any jam,need high pressure air purge;
3. If heat transfer performance fall largely,please stop and check;
4.The vibration of equipment during the operation may cause connection bolt loose. 
Therefore, the connection position should be checked every three months. 
5.The equipment must be operated under design pressure, overpressure operation is forbidden.