Yantai Funaike Heat Exchanger Co.,Ltd.

Products

Aluminum Plate-bar Radiator

Engineer Machinery Series

Home>Products>Aluminum Plate-bar Radiator>Engineer Machinery Series
Excavator-SY215

Excavator-SY215


luminum Plate-bar Heat Exchanger for Excavator(21mt)
  • Feature
  • Parameters

Feature

luminum Plate-bar Heat Exchanger for Excavator(21mt)

Parameters

Aluminum Plate-bar Heat Exchanger for Excavator(21mt) 
ModelSY215
ParametersCore Size: 1000X800X145mm                               
Core Size: 1196X990X400mm                         
Engine:  MITSUBISHI(118KW/2000rpm)                                  
Fan:  Sucked                                       
Heat Exchanger: Water 62KW  Oil 52KW Intercooler 12KW                                       
Radiator Operation Pressure: 0.3mpa                       
Oil Cooler Operation Pressure: 2mpa        
Intercooler Operation Pressure : 0.4mpa               
Feature /StructurePlate-bar structure with water radiator /oil cooler /intercooler structure . 
The advantage is compact structure,surface area can be 1000~2500m/m because of expansion of plate-fin heat exchanger with the quadratic surface.                               
AppplicationApplication to excavator  21mt 
AdvantageWith High Efficency of Heat Transfer;Well adapted,Plate-fin heat exchanger can be applied to: gas - gas, gas-liquid and liquid-liquid;Pressure Strength Resistant Capability is high.(Max 4.0Mpa);Low temperature resistant capability is strong(Ambient Tem.-65°C);Fin lodging resistance capability is strong, easy to maintain, flush.
Maintenance1.Regularly check internal medium quality of heat exchanger,if there is particles、floc matter etc, need exchange in time; 
2.Regularly check outside channel of heat exchanger,if there is any jam,need high pressure air purge;
3. If heat transfer performance fall largely,please stop and check;
4.The vibration of equipment during the operation may cause connection bolt loose. 
Therefore, the connection position should be checked every three months. 
5.The equipment must be operated under design pressure, overpressure operation is forbidden.